- Beijing Daelim Green EP TECH Co., Ltd.
- No.4 Business Building-2707, China Central Place, Chaoyang District, Beijing-100025, China
- +86-10-65003129
- 86-13910231168
- +86-10-65001715
- COFEKA CIA. LIMITADA
- KM 10,5 VIA A DAULE, GUAYAQUIL, ECUADOR
- 593-4-2100443
- 593-4-2100446
- 86-13910231168
- service@daelim-electric.com
>>Hydro Turbine System >>Turgo Turbine
Turgo Turbine
The impulse turbine can be divided into scoop turbine and inclined jet turbine:
1.Scoop turbine
Scoop blade is bucket-shaped leaves. Jet center line is tangent to the runner pitch circle, which is also known as (Pelton) turbine, which features: I.applicable head is high; II. simple structure; III.not influenced by carvitation erosion ; IV.higher cost effectiveness
- Product Details
- Specification
- Make an Inquiry
Impulse turbine
The impulse turbine can be divided into scoop turbine and inclined jet turbine:
1.Scoop turbine
Scoop blade is bucket-shaped leaves. Jet center line is tangent to the runner pitch circle, which is also known as (Pelton) turbine, which features: I.applicable head is high; II. simple structure; III.not influenced by carvitation erosion ; IV.higher cost effectiveness
Head for the Scoop turbine is available within 100m ~ 500m.Runner diameter is available within 0.55m ~ 1.5m, Capacity is available within 200~ 10000kW in our company.
2.Inclined jet turbine:
The water flows into and out of the runner slantways towards the main shaft.
which features:
I.It has a high efficiency area for the associated adjustment implementation of the runner blade and guide vane ;II.The axis of the blade axis and the turbine axis is bias, which can be installed more leaves to offer for application head; III.The structure is more complex.
The main parameters of turgo turbines | |||||||
Model |
Nozzle size (cm) |
performance paramete |
Diameter of main valve |
||||
water head (m²/s) |
water flow (L/S) |
Rotation speed (r/min) |
power (kw) |
speeder | |||
XJ02-W-32 | 1×6 | 25-90 | 0.06-0.114 | 625-1186 | 9.6-79.4 |
TT35 or Hand, electric governor |
φ250 |
1×7 | 25-100 | 0.082-0.164 | 625-1250 | 13-128 | |||
1×8 | 25-100 | 0.1069-0.2138 | 578-1154 | 19.7-149.9 | |||
1×9 | 30-100 | 0.1346-0.2458 | 633-1156 | 29.7-180.8 | |||
XJ02-W-40 | 1×7 | 45-120 | 0.11-0.179 | 671-1095 | 38-165 | φ300 | |
1×8 | 45-120 | 0.143-0.234 | 671-1095 | 49-215 | |||
1×9 | 35-120 | 0.16-0.296 | 592-1095 | 44-278 | |||
1×10 | 35-120 | 0.198-0.366 | 592-1095 | 54-345 | |||
1×11 | 35-120 | 0.208-0.386 | 592-1095 | 55-348 | |||
XJ02-W-40A | 1×9 | 125-160 | 0.302-0.342 | 1000 | 304-419 | φ350 | |
1×10 | 125-160 | 0.374-0.423 | 1000 | 376-524 | |||
1×11 | 125-160 | 0.394-0.445 | 1000 | 396-550 | |||
XJ02-W-50 | 1×11 | 45-120 | 0.271-0.443 | 536-876 | 96-417 | φ400 | |
1×12.5 | 45-120 | 0.35-0.572 | 536-876 | 126-539 | |||
1×13 | 45-120 | 0.369-0.602 | 536-876 | 134-567 | |||
XJ02-W-50A | 1×11 | 125-180 | 0.452-0.543 | 1000 | 438-775 | φ500 | |
1×12.5 | 125-180 | 0.584-0.70 | 1000 | 573-1001 | |||
1×13 | 125-180 | 0.629-0.755 | 1000 | 617-1093 |