>>Current Transformer & Potential Transformer >>High Voltage Transformer >>TYD-3566110220kV High Capacitor Voltage Transformer
TYD-3566110220kV High Capacitor Voltage Transformer
Summary
It is outdoor,single phase and oil capacitor voltage transformer,which is used for metering and relay protection of 35~220kv,50hz system.its capacitor divider is also used as coupling capacitor in carrier wave coupling device in power line unit.
- Product Details
- Specification
- Make an Inquiry
TYD-35/66/110/220kV high capacitor voltage transformer
Summary
It is outdoor,single phase and oil capacitor voltage transformer,which is used for metering and relay protection of 35~220kv,50hz system.its capacitor divider is also used as coupling capacitor in carrier wave coupling device in power line unit.
Service condition
Max. temperature:+45°C
Min. temperature: -40°C
Altitude: not more than 1000m(technical condictions through consulation when altitude is more than 1000m)
Environment pollution class: II, III, IV pollution area(if there are special requirement please indicate on contract.
Seismic fortification intensity: 9 degrees
Wind velocity: no more than 35m/s
Installation site: indoors or outdoors
System condition | ||||
System rated frequency(Hz) | 50HZ | 50HZ | 50HZ | 50HZ |
Rated primary voltage(KV) | 35/√3 | 66/√3 | 110/√3 | 220/√3 |
Rated secondary voltage(KV) | 0.1/√3 | 0.1/√3 | 0.1/√3 | 0.1/√3 |
Residual winding voltage(KV) | 0.1/3 | 0.1/3 | 0.1 | 0.1 |
neutral effectively earthed (Yes/No) | No | No | Yes | Yes |
Type |
Highest voltage for equipment (KV) |
insulation level | Rated burden |
Total Wt (Kg) |
|||
(KV) | (VA) | ||||||
Power frequency |
Lighting impulse |
Measuring winding 0.2 |
Measuring or protection winding 0.5(3P) |
Residual winding 3P |
|||
TYD35/√3-0.01H | 40.5 | 80(95) | 185(200) | / | 100 | 100 | 500 |
TYD35/√3-0.02H | 50 | 50 | 100 | 510 | |||
TYD66/√3-0.01H | 72.5 | 140(160) | 325(350) | / | 150 | 100 | 610 |
TYD66/√3-0.02H | 150 | 150 | 100 | 650 | |||
TYD110/√3-0.01H | 126 | 200(230) | 480(550) | / | 150 | 100 | 610 |
TYD110/√3-0.02H | 100 | 100 | 100 | 650 | |||
TYD220/√3-0.01H | 252 | 395(460) | 950(1050) | / | 150 | 100 | 840 |
TYD220/√3-0.02H | 100 | 100 | 100 | 940 |